O-Calc Pro Technical Note for version 5.0.3.18012 rev2 This O-Calc Pro Technical Note address remediation of two defects that were introduced with the release of O-Calc Pro Version 5.03 up to and including Build 5.0.3.18012, built on 2018-03-08 02:20 PM. It is recommended that the release O-Calc Pro Version 5.03 (5.0.3.18012), built on 2018-05-18 12:19 PM be download from the O-Calc Pro installation site to correct these defects. O-Calc Pro Installation site: (https://www.o-calcpro.com/PPL/NewVersionAvailable.html) Error in the Sag/Tension Calculation With the release of O-Calc Pro Version 5.03, the modeling of the O-Calc Pro tension and sag functionality was enhanced to better model how the wind interacts with the span geometry at oblique angles. The goal of this enhancement was to better model how the span’s blowout reacts to the wind at relative angles other than 0 and 90 degrees. Unfortunately, a calculation defect was introduced that overcompensated for this effect when tensions in spans were being modeled in either ‘Sag to Tension’ mode or ‘Tension to Sag’ mode. This overcompensation was most dramatic as the span angles deviated more from tangent angles. Note: this defect was not introduced if modeling tensions and sags in O-Calc Pro using Static, Slack, or Table mode. More information on how O-Calc Pro can model tensions and sags on conductors and cables using several different methods can be found on the O-Calc Pro WIKI page. See: http://o-calcpro.com/wiki/2017/05/16/tension-types-and-sag-explained/). Error in Display Attachment Heights for Segmented Poles O-Calc Pro can model manufactured, non-wood, segmented poles. This are typically steel or fiberglass poles that are manufactured in segments and then stacked in the field during installation. O-Calc Pro models these segmented poles as separate segments so that the amount of overlap can be adjusted to either the manufactures specifications and/or how the pole was constructed in the field. With earlier build of O-Calc Pro Version 5.03, both the O-Calc Pro 3D View and the Schematic View displayed incorrect attachment heights when modeling these segmented poles. These displays were failing to properly account for the setting depth of the bottom most segment. It should be emphasized that defect did not affect the calculations, only how the model was being displayed. O-Calc Pro 5.03 is available in both manual and installer based versions. Depending on your environment you may wish to use the installer or to manually install the files. For those using the installer it is highly recommended that you first do the following: 1) Uninstall your current version. 2) Manually navigate to "C:\Program Files (x86)\Osmose\O-Calc Pro". 3) Delete the "bin" folder there. This prevents problems caused by certain aggressive Anti-Virus programs that incorrectly prevent the removal of selected components form older versions that prevent proper operation of O-Calc Pro For those wishing to install O-Calc Pro 5.03 manually you may use the .ZIP version and replace your existing "C:\Program Files (x86)\Osmose\O-Calc Pro\Bin" folder with the "bin" folder from the .ZIP